WebThe high-leg delta (also known as the wild-leg, stinger leg, bastard leg, high-leg, orange-leg, red-leg, and dog-leg delta) is a three-phase electrical service connection. ... The … WebJun 3, 2024 · Minor damage often occurs during contact sports, such as football or wrestling, when the brachial plexus nerves get stretched or compressed. These are called stingers or burners, and can produce the …
Electrical stinger leg
Did you know?
WebOct 16, 2013 · The high-leg conductor is also called the “wild leg,” “stinger leg,” or “bastard leg.” Other important NEC rules relating to the high leg … WebNov 25, 2024 · Electrical Engineer. Nov 23, 2024. #3. Technically the gear itself does not care, but the breakers do. There are some breakers referred to as “slash rated”, meaning …
WebJun 5, 2015 · 9,883 Posts. #6 · Jun 4, 2015. 3D Electric said: I looked up a QO and it shows a rating of 120/240 so I do not see why that installation would be unacceptable. When a breaker is 'slash rated', the lower voltage is line to … WebMar 7, 2010 · 2. waross (Electrical) 5 Mar 10 19:57. Single phase loads are 120V, 120/240V or 240V. A maximum of 120V to ground. Three phase loads are 240V. These are the voltages of a four wire delta system.It doesn't matter if the delta is open or closed. Single phase loads should not generally be connected to the wild phase.
WebWhat is known as a "stinger leg" is the higher voltage end of a 3-phase delta found mostly in North America. It is 240 volts relative to ground. Modern electronic devices using switch mode power supplies with 100-240 volt input, like nearly all computers, would handle it … WebJan 19, 2006 · This gives 120V from, say A and C to ground and 208V from B (the 'stinger') to ground. For a standard ungrounded open delta, the voltage from any leg to ground is indefinate. If one corner of the open delta is grounded, there will be 240V L-G from each of the other two legs. Unless you have a center tapped winding, there's no way to get 120V.
WebDec 30, 2006 · 4 Wire, 3 phase Delta, 120/208 Volts. This type of electric service is sometimes called a wild leg or stinger system because one of the legs is 208-240 volts …
WebSep 9, 2024 · High leg delta, also known as wild-leg, stinger leg, bastard leg or high leg is a type of electrical service connection for three phase electric power installations. It is used when both single and three phase power is desired to be supplied from a three phase transformer. How many volts is a Delta high leg? Applications. mckinney pharmacy decatur gaWebA four-wire delta (4WD) electrical service is a three-phase delta service with a center-tap on one of the transformer windings to create a neutral for single-phase loads. ... “wild-leg”, “stinger leg”, or “wild phase” service, … lick grey 03WebBy using a high leg delta connection, we can get two 120V supplies, three 240V supply and a 208V supply. The phase with 208V supply to the ground is called High-Leg or Orange leg. This conductor needs to be marked permanently by orange outer finish where ever connection is made. lick gracevilleWebFilmtools Stinger 12/3 SJO Cable (Extension Cord) - 50'. $113.81. Eligible for FREE Shipping. Add to Cart. Add to Wish List Add to Compare Share Item Report Issue. SKU: … mckinney pharmacy springdale arWebOct 26, 2014 · If you have a wild leg then you do not have a 208/120V panel you have a 240V delta panel. Voltage on any phase to any other phase is 240V. A to B 240V, A to C 240V, B to C 240V, BUT.... Voltage from B to ground is 208V. That is why it is a wild leg, or high leg, or stinger, or bastard son of %$!! leg. electricalist Senior Member Location … mckinney pharmacy hoursWebJun 21, 2024 · This is why it is the high leg, because that 20.8 centimeters, represents 208V, instead of 120V. As you can see, the high leg system is 240V phase-to-phase, and only for phases A and C is it 120V to neutral, while phase B is a special phase that is 208V to neutral. Now consider the 120/208V three phase wye system. lick grey 02WebTerms in this set (40) A delta three-phase power supply provides: 240 V between the legs. A transformer uses this electrical principle to increase or reduce voltage with no moving parts or contacts. Induction A wye three-phase power supply provides: 208 V between the legs. AC generators work by: Turning a coil of wire through a magnetic field. lick granulomas treatment